A Six-Center Candida auris Study Tested 2,020 Axilla-Groin Swabs: Sensitivity Was 94.8% With Results Under Two Hours.

Candida auris can drive persistent healthcare outbreaks, while culture is slowed by growth and possible misidentification. A six-center evaluation tested 2,020 bilateral axilla-groin swab specimens: 1,930 prospectively and 90 retrospectively. Patients came from inpatient, intensive care, emergency, and long-term acute-care settings.

Performance was strong but discordance still matters
Against culture followed by MALDI-TOF identification, the direct molecular assay showed 94.8% sensitivity, 98.7% specificity, 98.6% accuracy, and kappa of 0.80. Only 1.4% of results were discordant, and bidirectional sequencing of ITS and 28S D1/D2 regions helped resolve disagreements. Results were available in under two hours.
A molecular-positive, culture-negative result may reflect low burden, nonviable cells, or culture failure. The opposite may reflect uneven sampling, inhibition, or concentration near the detection limit. Limits of detection were 127 CFU/mL for clade I and 260 CFU/mL for clade IV, so equivalent low-level behavior across clades should not be assumed.
Four skin areas require one controlled route
Screening should define area, pressure, passes, time, and order across both axillae and groins. Moisture, bathing, topical products, and chlorhexidine decolonization can change burden. When one device crosses all four sites, its tip must not touch the tube rim, gloves, or surrounding skin.
Culture-positive specimens averaged Ct 25.1, while molecular-positive, culture-negative specimens averaged Ct 33.6. Borderline signals need internal controls, repeat rules, and low-positive lot checks. Unused swab blanks and transport-medium qualification can identify material inhibition.
Speed pays when isolation starts earlier
A two-hour result can accelerate precautions and contact investigation, but prevalence and patient history still guide interpretation. Admission screening, outbreak contacts, and post-decolonization follow-up may need different algorithms. Site, previous colonization, and collection date belong with every result.
Implementation should also capture operator, ward, sampled side, time since decolonization, and visible skin condition. Paired external controls should be processed on every shift during initial deployment, and invalid runs should be reviewed before patient reports are released. Staff competency should be reassessed after workflow changes. Serial screens should use the same timing and motion. A device-lot change deserves a low-positive bridge check before trends are interpreted as clearance or renewed colonization.
Changfeng Medical can supply flocked axilla-groin swabs, bilateral collection kits, low-binding tubes, and prefilled preservation media. Device qualification can test fungal recovery, low-burden repeatability, inhibition, and consistency across a four-site procedure. The assay shortens detection; disciplined collection makes that speed useful.
Source: six-center performance evaluation of direct Candida auris testing.